Add to Cart
FUJI Hairline Stainless Steel with Machine Roomless Passenger Elevator
8000kg 1.0m/S Passenger Machine Room Less Lift With Gearless Lift Motor For Elevator
FUJI machine roomless passenger elevator cancels the machine room, reduces total area of the elevator equipment and flexibly utilizes the effective space. It has the stronger contemporary sense and the more beautiful construction outine.
The host and control device are designed al the shaft top to prevent from occasional water-inlet in the shaft which damages the drive device. In this way, it guarantees a highly reliable system.
Blended Into the Construction,Easily and Leisurely
FUJI machine roomless passenger elevator need only one independent hoist-way and do not need the presence of machine rooms. The architects and developers are allowed to conduct designing in a freer way.
Machine Roomless Elevator Specifications
Persons | Load (kg)
| Speed (m/s)
| Net size of car(mm) C.WxC.DxD.H
| Net size of door(mm) 2P Center opening
| Shaft size(mm) | ||
H.WxH.D | HR.H | PIT | |||||
6 | 450 | 1.0 | 1100x1100x2300 | 800x2100 | 2050x1850 | 4000 | 1500 |
8 | 630 | 1.0 | 1400x1100x2300 | 800x2100 | 2250x1900 | 4200 | 1500 |
1.5/1.75 | 4400 | 1600 | |||||
10 | 800 | 1.0 | 1400x1350x2300 | 800x2100 | 2250x1950 | 4200 | 1500 |
1.5/1.75 | 4400 | 1600 | |||||
2.0 | 4800 | 1800 | |||||
2.5 | 2000 | ||||||
13 | 1000 | 1.0 | 1500x1550x2300 | 900x2100 | 2350x2150 | 4200 | 1500 |
1.5/1.75 | 4400 | 1600 | |||||
2.0 | 4800 | 1800 | |||||
2.5 | 2000 |
FAQ
1. Are the elevator wire ropes durable?
The elevator wire rope has special provisions and requirements. Configuration is not only for wire rope and rated load, but also considered the size of the traction, as a result, the tensile strength of wire rope is greater than the weight of the lift. The safety factor is equipped with more than four wire rope. So it won’t break at the same time.
2. Is it dangerous for power failure suddenly during the elevator running?
If it occurs, the elevator will automatically stop due to the electrical and mechanical safety device. In case of power failure,elevator brakes will automatically taken. In addition, the power supply departments such as planned outage, prior notice are also operating.
3. Will us be hurt when it closed suddenly?
In the closing process, if people touch the hall door, the door of elevator will automatically restart without any danger. With anti clamping switch, once the gate touched, this switching action make the elevator unable to be closed and even reopened. In addition, closing force is also available here.
4. How the elevator running?
Elevators are operated with a counterweight wire rope through the (tractor) traction drive, making ups and downs on the guide rail.
5. Is the escalator installation complicated?
We believe the functions of an escalator are not necessarily proportional to the operation complexity. Therefore, escalators designed by us apply an integrated structure, so that the equipment is more precise and more efficient and allows easier and more convenient commissioning.
6. Do you have any cerifications?
Yes, we do with ISO9001 / CCC / CE Certificates for u.